Showing results: 811 - 825 of 2628 items found.
-
ZERA GmbH
Our stationary and mobile instrument transformer test systems are used to test current and voltage instrument transformers. Among other things, accuracy testing, demagnetization and insulation testing are possible.
-
Hubbell Power Systems Inc
Phasing testers are used on grounded and ungrounded alternating current systems to check high-voltage fuses, test for correct phase connections and test for the absence of high voltage on de-energized lines or apparatus.
-
ROM-Elektronik GmbH
Alternating electrical fields occur when an alternating voltage is applied to an electrical line. This generates alternating currents in the human body. This can be measured on the body with a measuring device (voltmeter) in millivolts (mV).
-
33020 -
Chroma ATE Inc.
High channel density with 8 channels per card 6V-12V independently programable voltage level Max. current gang feature providing max. 4A output per card
-
TP300W 600W Series -
Twintex Electronics Co., Ltd
The TP300W/600W series are linear DC power supplies with 1 channel, 300W/600W output. In constant voltage and current operations, the power supply provides high regulation and low ripple & noise.
-
LT45 -
Trailer Light Tester
The LT45 tester performs both light & electric brake function testing. It incorporates a digital display for checking voltage and current draw of tested circuit. This tester is powered by an internal battery.
-
B1505AP -
Keysight Technologies
B1505AP provides eight different pre-configured packages that satisfy a wide variety of power device measurement requirements. The package can be selected according to voltage / current range and the requirement for capacitance measurement.
-
N6774A -
Keysight Technologies
The Keysight N6774A DC Power Module, 35V, 8.5A, 300W, is a basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price.
-
PEC-NS01 -
Peccell Technologies, Inc.
Original measuring device with a simple command●RS-232C connection●Easy measurement with simple commands●Analog output terminal for current and voltage values●Equipped with PEC-L01 shutter control function
-
40-139-201 -
Pickering Interfaces Ltd.
The 40-139 2A Relay Series is suitable for applications requiring medium power switching with high density. Featuring 2A current capacity and voltages to 300VDC/250VAC it is useful for cost critical applications.
-
40-139-101 -
Pickering Interfaces Ltd.
The 40-139 2A Relay Series is suitable for applications requiring medium power switching with high density. Featuring 2A current capacity and voltages to 300VDC/250VAC it is useful for cost critical applications.
-
ST-1520 -
MRC ltd.
Capable of measuring earth voltage.2mA measuring current permits the testing of earth resistance without tripping earth leakage current circuit breakers in the circuit.Auto power off function.The timer operates automatically for approximately three to five minutes when the "push button switch" and "timer on button" are pressed together.
-
M-270 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*True rms reading for ACA and ACV.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.
-
RNT-5A -
Neutronics Manufacturing Co.
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).